Insulation Calculator

Pick your state or climate zone and where you insulate, then get the target R-value, thickness and how many batts or bags to buy.

Units
Where you insulate
R

Recommended for zone 4 (4A, 4B): R-60.

R-3.2 per inch (UMD Extension)

sq ft
Framing spacing
%

Cut ends, trimmed batts and odd bays. 10% is usual.

Fiberglass batts for 1,000 sq ft of attic floor

414batts

Two layers, R-30 between the joists and R-30 across them: R-60 in all.
Target
R-60
You reach
R-60
Thickness
19 in
Ceiling drywall, framing 16 in on center19 in5 ½ in
The math
  1. Target

    Zone 4 (4A, 4B), attic floor = R-60

  2. Batts

    1,000 sq ft × 1.1 ÷ (16 in × 48 in = 5.33 sq ft) = 207 batts of R-30

  3. Second layer

    1,000 sq ft × 1.1 ÷ (16 in × 48 in = 5.33 sq ft) = 207 batts of R-30

Recommended R-value for attic floor, by zone (ENERGY STAR)
  • Zone 1R-30
  • Zone 2R-49
  • Zone 3R-49
  • Zone 4R-60
  • Zone 4C marineR-60
  • Zone 5R-60
  • Zone 6R-60
  • Zone 7R-60
  • Zone 8R-60

Material list

1,000 sq ft of attic floor, zone 4 (4A, 4B), target R-60

QuantityItem
207batts

Owens Corning R-30 batts, 9.5 in

16 in bays, 48 in long, 10% waste

207batts

Owens Corning R-30 batts, 9.5 in

second layer across the joists, 16 in wide, 48 in long, 10% waste

How much insulation you need depends on where you live and where it goes. ENERGY STAR recommends R-60 for an uninsulated attic in climate zones 4 to 8, R-49 in zones 2 and 3 and R-30 in zone 1. In fiberglass batts, R-60 over a 1,000 sq ft attic on joists 16 in apart is two layers of R-30, about 414 batts with 10% waste and 19 inches deep.

How the insulation calculator works

Pick where you insulate and your state or climate zone. The calculator looks up the recommended R-value, then sizes the material you choose:

Thickness = target R ÷ R per inch; batts = area × (1 + waste) ÷ (framing spacing × batt length), per layer

Blown-in insulation is counted from the manufacturer's bag chart instead, and rigid foam in 4 × 8 ft boards, one set per layer.

Worked example: attic in zone 4, fiberglass batts

  • Target R-60 (ENERGY STAR, zones 4A and 4B)
  • No single batt reaches R-60 (Owens Corning EcoTouch goes up to R-49 at 14 in), so the calculator uses two layers: R-30 + R-30, each 9½ in thick
  • One R-30 batt fills a 16 in bay 48 in long: 16 × 48 in = 5.33 sq ft
  • 1,000 × 1.1 ÷ 5.33 = 206.3, so 207 batts per layer, 414 in all

The second layer goes across the joists so it covers their tops. With R-49 as the target, one layer of R-49 batts does it.

Recommended R-values by climate zone

ZoneAttic, uninsulatedAttic, 3 to 4 in alreadyFloorWood frame wall (new)Basement wall (new)
1R-30add R-25R-13R-13none
2R-49add R-38R-13R-13none
3R-49add R-38R-19R-20 or R-13 + R-5 ciR-13 or R-5 ci
4 (A, B)R-60add R-49R-19R-20 + R-5 ci or R-30R-13 or R-10 ci
4C, 5, 6R-60add R-49R-30R-20 + R-5 ci or R-30R-19 or R-15 ci
7, 8R-60add R-49R-38R-20 + R-5 ci or R-30R-19 or R-15 ci

Attic and floor values are ENERGY STAR's retrofit recommendations, which are based on 2021 IECC Table R402.1.3. Wall and basement values are the code minimums for new homes from that table, as published by the Building America Solution Center (PNNL). "ci" is continuous insulation: rigid foam over the studs. The bar chart under the result draws the column for your location.

Insulation calculator for the attic

Turn on "The attic already has 3 to 4 in of insulation" and the target becomes the R-value to add on top: R-49 in zones 4 to 8. For loose-fill, blow it rather than lay batts; the blown in insulation calculator counts bags from the Owens Corning, Greenfiber and Johns Manville charts and subtracts what is already there.

Walls

A 2x4 stud is 3½ in deep and a 2x6 is 5½ in (ProWood). DOE notes that 2x4 walls hold R-13 or R-15 batts and 2x6 walls R-19 or R-21. That is why the IECC asks for R-20 plus R-5 of foam sheathing in zones 4 and colder: no batt reaches R-20 in a 2x4. The calculator only offers batts that fit the cavity and tells you when the cavity falls short. For 400 sq ft of 2x4 wall with R-13 batts (15 in wide, 93 in long, 10.33 sq ft per bay), that is 43 batts with 10% waste.

Floors and basement walls

Floors over a crawl space or garage get R-19 in zone 4 and R-30 from zone 4C up. For basement walls, rigid foam against the concrete counts as continuous insulation: R-10 is 2 in of XPS at R-5 per inch.

R-value per inch

MaterialR per inchSource
Fiberglass batts3.2UMD Extension
Mineral wool3.1UMD Extension
Loose-fill cellulose3.7UMD Extension
Loose-fill fiberglass2.2UMD Extension
EPS board4.0 to 4.5UMD Extension
XPS board5.0 to 5.5UMD Extension
Polyiso board5.6 to 8DOE
Spray foam, open / closed cell3.6 / 5.5 to 6.5DOE

The calculator uses the low end of each range for boards, so the thickness is never short. R-49 of blown cellulose is 49 ÷ 3.7 = 13¼ in; in rigid foam, R-10 of XPS is 10 ÷ 5 = 2 in, and a 1,000 sq ft wall takes 35 boards of 4 × 8 ft with 10% waste.

Finding your climate zone

Choosing a state fills in its most common 2021 IECC zone, counted by county from PNNL's "Guide to Determining Climate Zones by County". Many states span several zones (Texas runs from 1 to 4, California from 2 to 6), so the page flags them: check your county in that guide and set the zone directly.

Next steps

For a sprayed air seal on rim joists or a roof deck, the spray foam calculator turns area and thickness into board feet and kits, and the spray foam insulation cost calculator prices it installed. Closing up the walls afterwards? The drywall calculator counts the sheets. Better insulation lowers the heat load: size the system with the BTU calculator. More tools are in drywall, paint and walls.